ARcare® 92848

Product Overview

ARcare® 92848 is a double-sided heat sealing tape. It consists of a white polyester carrier coated on both sides with a thermoplastic adhesive and protected by clear polyester release liners.

Product Applications

The typical use for this product is as a component material for use in joining polymer and metalized plastic substrates. The applications include in-vitro diagnostic test devices such as capillary and lateral flow designs.

Features and Benefits

  • Conformable and easily applied to substrates
  • Provides strong bonds to polyester, polystyrene, polycarbonate, polymethyl methacrylate and metalized plastic substrates

  • Good sealing properties for containment of fluids

  • Non-interfering with reagent chemistries

  • Processing and converting capabilities with minimal gumming effects

  • Water contact angle of ~ 70°-90°

  • Can be used in specialized device designs requiring tight thickness tolerance

Product Construction

Typical Values* Description
Liner thickness 2.0 mil | 50 μm Clear polyester release liner
Adhesive thickness 0.9 mil | 23 μm MA-77 heat sealing adhesive
Carrier thickness 2.0 mil | 50 μm White polyester film
Adhesive thickness 0.9 mil | 23 μm MA-77 heat sealing adhesive
Liner thickness 2.0 mil | 50 μm Clear polyester release liner
Total thickness 3.8 mil | 96 μm (Excluding liner)

*All stated values are nominal and should only be used as a guide for selection. They are not specifications.

Safety Data

Adhesive has passed cytotoxicity tests conducted by an independent laboratory. Additional safety information is available upon request.

Technical Properties

Attribute* Typical Values* Test Method*
T-peels using Melinex 329 Backing 45 oz/inch | 12.5 N/25mm 3 second 60°C heat seal, 50 psi, 2.36 in/min, 24 hour dwell
Liner Release (both sides) ~30 g/2’’ 180 degrees, 300 ipm
Recommended storage of unconverted product 70°F ± 20°F | 21°C ± 11°C
50% ± 20% RH | 50% ± 20% RH
Shelf life of unconverted product Not to exceed one year from date of manufacture